NPSH Available Calculator

Net positive suction head available at the pump: elevation-adjusted atmospheric pressure, static suction head or lift, vapor pressure at water temperature, and suction-side friction — compared against the pump's NPSHr with margin. Runs entirely offline; inputs persist in this browser via localStorage.

Use limits: Clean water assumed (vapor pressure table is for water; specific gravity ≈ 1). Entrained air, dissolved gases coming out of solution, and vortexing at the intake all rob suction performance in ways NPSH arithmetic doesn't capture — a passing NPSHa with a bad intake still cavitates. NPSHr comes from the manufacturer's curve at the actual operating flow, not the rated point.
Site & Water
Suction Conditions

Use the LOWEST credible water level — NPSH is worst at low wet well level.

Pipe + fittings + strainer/foot valve from the source to the pump flange. A half-plugged strainer is friction too.

Hydraulic Institute suggests a margin (commonly 2–5 ft or a 1.1–1.3 ratio); the pump spec may state one.

How the Numbers Are Derived

The NPSHa equation

NPSHa = h_atm ± h_static − h_vp − h_friction (all in feet of water)

Atmospheric pressure falls with elevation per the standard atmosphere: P(psia) = 14.696 × (1 − 6.8754×10⁻⁶ × elev)^5.2559, converted to feet at 2.31 ft/psi. Static head is positive for flooded suction, negative for lift. Vapor pressure is interpolated from the water table below and subtracted because water flashes to vapor once local pressure falls to it — that flashing is cavitation.

Water vapor pressure table (psia)

32°F: 0.089 · 40°F: 0.122 · 50°F: 0.178 · 60°F: 0.256 · 70°F: 0.363 · 80°F: 0.507 · 90°F: 0.698 · 100°F: 0.949 · 110°F: 1.275 · 120°F: 1.692 · 130°F: 2.223 · 140°F: 2.889 · 150°F: 3.718 · 160°F: 4.741 · 170°F: 5.992 · 180°F: 7.510 · 190°F: 9.339 · 200°F: 11.526 · 212°F: 14.696

Linear interpolation between points. Note how fast this climbs with temperature — the same suction that works on 60°F water can cavitate on 130°F digester recirculation.

Field diagnosis notes

References

  1. ANSI/HI 9.6.1 — Rotodynamic Pumps: Guideline for NPSH Margin. https://www.pumps.org/
  2. Karassik et al., Pump Handbook — NPSH fundamentals.
  3. Manufacturer's certified pump curve — NPSHr at the actual operating flow (governing input).